Some characteristics of positive and bipolar lightning flashes recorded on the Santis tower in 2010 and 2011

Romero, Carlos (Swiss federal Institute of Technology (EPFL), Lausanne, Switzerland) ; Rubinstein, Marcos (School of Management and Engineering Vaud, HES-SO // University of Applied Sciences Western Switzerland) ; Rachidi, Farhad (Swiss federal Institute of Technology (EPFL), Lausanne, Switzerland) ; Paolone, Mario (Swiss federal Institute of Technology (EPFL), Lausanne, Switzerland) ; Rakov, Vladmir A. (Department of electrical and Computer Engineering, University of Florida, Gainesville, FL, USA) ; Pavanello, Davide (School of Engineering, HES-SO Valais-Wallis, HEI, HES-SO // University of Applied Sciences Western Switzerland)

We present an analysis of measured current waveforms associated with positive and bipolar flashes recorded on the Säntis tower, Switzerland, from May 2010 till January 2012. The overall number of recorded flashes in the considered period was 201, of which 30 were of positive polarity (effectively transported positive charge to ground) and three were bipolar. The recorded positive flashes were mainly concentrated in the summer months, August being the month during which most of them occurred (6 events in 2010 and 16 events in 2011). The observed positive flashes are characterized by a median peak current of 11.8 kA, and a median flash duration of 80 ms. These values are consistent with those associated with the data recorded at the Gaisberg Tower in Austria. On the other hand, the amount of transferred charge is substantially larger in our dataset, with a median value of 169 C (6 times as large as the values obtained in Monte San Salvatore and in Japan, and 3 times as large as the value obtained in Austria). Eight flashes out of 30 transported positive charge to the ground in excess of 500 C. The obtained results confirm also the findings of Saba et al. according to which positive lightning flashes may combine high peak currents with high charge transfers (or flash durations). The three bipolar flashes recorded during the considered time period occurred during one storm occurred on August 27, 2011. The relative number of bipolar flashes (1.5%) is found to be lower than the values reported in previous studies in Austria and in Switzerland (3 to 6%). On the basis of the classification proposed by Rakov, two of the three observed bipolar flashes belonged to Type 2 and one to Type 3.


Keywords:
Conference Type:
full paper
Faculty:
Ingénierie et Architecture
School:
HEI-VS
HEIG-VD
Institute:
IICT - Institut des Technologies de l'Information et de la Communication
Institut Systèmes industriels
Publisher:
Vienna, Austria, 2-7 September 2012
Date:
2012-11
Vienna, Austria
2-7 September 2012
Pagination:
5 p.
Published in:
Proceedings of 2012 International Conference on Lightning Protection (ICLP), 2-7 September 2012, Vienna, Austria
DOI:
ISBN:
978-1-4673-1897-6
Appears in Collection:

Note: The status of this file is: restricted


 Record created 2020-10-20, last modified 2020-10-27

Fulltext:
Download fulltext
PDF

Rate this document:

Rate this document:
1
2
3
 
(Not yet reviewed)